Products
Simplify Your Measurements with Micran’s Scalar Network Analyzers
Supplier: Micran
Key Features
Wide frequency range: 10 MHz to 4/20/40 GHz
Wide output power level range: -90/-20 to 15 dBm
High frequency and output power stability
Transmission and Reflection factor, VSWR, Group Delay Time measurements
Power Meter and Frequency Synthesizer modes
Impulse devices measurement
SCPI Language Compatibility
Generate Pulse and CW signals by Micran’s Frequency Synthesizers
Supplier: Micran
Key Features
Wide frequency range: 0.01/10 MHz to 4/20/40 GHz
Wide output power level range: -130/-90/-20 to 15 dBm
Highly stable output frequency and power level
Low phase noise: -125 dBc/Hz for 10 kHz offset from 1 GHz carrier
Pulse modulation with pulse Rise/Falloff less than 10 ns and On/Off ratio over 70 dB
SCPI Language Compatibility
Advanced signal creation with Micran’s Vector Signal Generators
Supplier: Micran
Key Features
Frequency range: 10 MHz to 6 GHz
High power range -90 dBm to +12 dBm
Analog and digital modulation (AM, FM, PM, Pulse, QAM, PSK, FSK, MSK)
Low phase noise: -130 dBc/Hz for 20 kHz offset from 1 GHz carrier
RF Modulation bandwidth 100 MHz
Playback of precalculated waveforms with sampling rate up to 125 MHz
SCPI Language Compatibility
Supplier: Micran
Characteristic features
Measurement of S-parameters from 10 MHz to 20 GHz
Dynamic range more than 100 dB
Measurements in the pulsed mode: "point in the pulse", "pulse profile"
Measurement of parameters of frequency-converting devices with vector calibration
Vector network analyzers "Panorama"
Supplier: Micran
Characteristics
Operating frequency range from 0.3 / 10 MHz to 13.5 / 26.5 GHz
Wide dynamic range: up to 145 dB
High output power: up to +15 dBm
High track stability: 0.06 dB / ° C
Low road noise: 0.002 dB
Measuring instruments of noise factor X5M
Supplier: Micran
Characteristics
range of operating frequencies from 10 MHz to 20 GHz;
the noise figure and the transmission factor;
measurement of frequency converters with fixed and external heterodyne;
built-in thermostatically controlled preselector;
high speed of measurements;
external converters allow to extend the range of operating frequencies up to 50 GHz;
the ability to control through SCPI commands for use in test and measurement systems.
Supplier: Micran
Key Features
Frequency range: 100 Hz to 20/50 GHz
Third-order intercept (TOI) level up to +20 dBm
DANL < -165 dBm/Hz
Low Phase Noise -125 dBc/Hz at 1 GHz signal from 100 kHz offset
High Frequency Reference Accuracy ±0.1 ppm
Resolution Bandwidth Range 1 Hz to 10 MHz
Built-in input attenuator and thermostatic YIG-preselector
Built-in Low-noise Amplifier
SCPI Language Compatibility
Complex for measuring the parameters of PPM K2M-101 modules
Supplier: Micran
Characteristics:
- full characterization of the module in less than 45 seconds at 100,000 measurements;
- performance of all necessary measurements for one accession of the MRP;
- the configuration of the complex for the solution of a specific problem.
Complex for measuring S-parameters of multiport devices K2M-102
Supplier: Micran
Complex K2M-102 is designed to measure S-parameters of multiport RF and microwave devices. The two-port vector network analyzer P4M-18 with the port expansion unit and support of the electronic calibrator allows to measure the parameters of devices having up to 32 ports.
Complex for the calibration of noise generators K2M-901
Supplier: Micran
Complex K2M-901 is designed for the calibration of noise generators in the frequency range from 10 MHz to 20 GHz. The excess relative noise temperature (HSS) of the noise generator (GSH) is measured by comparing the noise power of the measured and reference GSN.