Unique feature of the Uriscan-BK device is the simultaneous determination of protein concentration in urine (pyrogallol red method), creatinine concentration in urine (Jaffe method) and automatic calculation of protein/creatinine ratio.

Calculation of the ratio: protein / creatinine in the morning portion of urine is a modern alternative to the determination of protein concentration in the daily urine sample, which for many years was the "gold standard" in the diagnosis of proteinuria. Since the value of the protein-creatinine ratio in the morning urine portion is clearly correlated with the level of daily proteinuria, in all current clinical guidelines of the professional medical communities, it is recommended to determine the protein/creatinine ratio.

Distinctive features of the analyzer URI SCAN-BK
Determination of protein in the urine is carried out by the method of pyrogallol red. This method is sensitive to all protein fractions. It allows you to accurately determine the concentration of protein in the urine in proteinuria of different Genesis.
Determination of creatinine in the urine is carried out by the Jaffe method. This is a standard, unified method for determining the concentration of creatinine in the urine.
The protein/creatinine ratio is calculated automatically. No additional operations or auxiliary calculations are needed. The result is displayed and printed on the check.
Only 3 buttons are used to control the analyzer. 5 minutes are enough to train a technician and put the device into operation.
Convenient step-by-step menu structure: at each stage the device gives a hint what to do next.
Technical characteristics of the analyzer URI SCAN-BK
The designated parameter protein, creatinine, protein/creatinine ratio
Range of measured concentration
Protein: 0,01- 8,0 g/l
Creatinine: 0,01- 10,0 g/l
Inaccuracy of measurements ≤ 8%
The sample size for the study
Creatinin — 10 microliter
Protein — 20 microliter
Used method
Protein — method using pyrogallol red dye
Creatinine — Jaffe method
The display of the result of the study
On the device screen
Printing on the printer
Printer Built-in thermal printer
Output time of the device on the working mode No more than 5 seconds after switching on
Sample tubes used Standard borosilicate glass tubes with an inner diameter of 10 mm
Power consumption No more thna 18 W
Ability to connect a computer Yes
Dimensions 260х160х90 mm
Weight 0,8 kg
Warranty period 12 months
Consumables for working on the analyzer
Standard borosilicate glass tubes 5 ml (size 75=12 mm, 5 ml) with an inner diameter of 10 mm.
Set of reagents uni-Test-BM, 500 opr. (produced by Ailiton LTD).
The set:
Pyrogallol red dye — 500 ml.
Protein calibration solution 1 g/l
Protein calibration solution — 0,2 g/l
Set of reagents Creatinin-UTS (produced by Ailiton LTD).