Autorefractometers VX130+
Succeed in all your diagnostics glaucoma and keratoconus detection identification of patients for cataract surgery with premium and/or toric implants dentification of patients for refractive surgery.
Part number:
Supplier:
Visionix RusDescription
The VX130 +combines state-of-the-art technologies and provides essential data for an improved treatment of patient. The VX130+ is the ideal patient monitoring system.
Technical specifications
General
Height 570 mm
Width 312 mm
Depth 530 mm
Weight 25 kg
Voltage 100-240 VAC, 50/60 Hz, 300 W
Display: 10.1” (1024 x 600) TFT screen, Multi-touch screen
Observation area ø 14 mm
Pachymetry, IC (irido corneal) angle and pupillometry
Method • Continuous vertical scan with the Scheimpflug camera
Pachymeter measuring range camera
Pachymeter resolution • 150-1300 μm
IC angle measuring range • +/- 10 microns
IC resolution • 0°-60°
Pupil illumination • 0.1° • Blue light 455 nm
Retro illumination
Corneal topography by specular reflection
Number of rings • 24
Number of measuring points • 6,144
Number of points analyzed • More than 100.000
Diameter of covered corneal area at 43D • From 0.75 mm to more than 10 mm
Measurement range • From 37.5 D to 56 D
Repeatability • 0.02 D
Method • Placido rings
TONOMETER
Measurement range • 7 mmHg to 44 mmHg
GENERAL
Alignment • XYZ automatic
Display • 10,1” (1 024 x 600) TFT screen Multi-touch
Observation area • screen
Medical directive • ø 14 mm
Output • EC MDD 93/42/EC modified by directive 2007/47/EC • RS232 / USB / VGA / LAN
Power mapping and refraction
Spherical power range • -20D to +20D
Cylinder power range • 0D to + 8D
Axis • 0 to 180°
Measuring area • Min. ø 2 mm – Max. 7 mm (3 zones)
Number of measuring points • 1,500 points
Acquisition time • 0.2 sec
Method • Shack-Hartmann
Technical specifications
General
Height 570 mm
Width 312 mm
Depth 530 mm
Weight 25 kg
Voltage 100-240 VAC, 50/60 Hz, 300 W
Display: 10.1” (1024 x 600) TFT screen, Multi-touch screen
Observation area ø 14 mm
Pachymetry, IC (irido corneal) angle and pupillometry
Method • Continuous vertical scan with the Scheimpflug camera
Pachymeter measuring range camera
Pachymeter resolution • 150-1300 μm
IC angle measuring range • +/- 10 microns
IC resolution • 0°-60°
Pupil illumination • 0.1° • Blue light 455 nm
Retro illumination
Corneal topography by specular reflection
Number of rings • 24
Number of measuring points • 6,144
Number of points analyzed • More than 100.000
Diameter of covered corneal area at 43D • From 0.75 mm to more than 10 mm
Measurement range • From 37.5 D to 56 D
Repeatability • 0.02 D
Method • Placido rings
TONOMETER
Measurement range • 7 mmHg to 44 mmHg
GENERAL
Alignment • XYZ automatic
Display • 10,1” (1 024 x 600) TFT screen Multi-touch
Observation area • screen
Medical directive • ø 14 mm
Output • EC MDD 93/42/EC modified by directive 2007/47/EC • RS232 / USB / VGA / LAN
Power mapping and refraction
Spherical power range • -20D to +20D
Cylinder power range • 0D to + 8D
Axis • 0 to 180°
Measuring area • Min. ø 2 mm – Max. 7 mm (3 zones)
Number of measuring points • 1,500 points
Acquisition time • 0.2 sec
Method • Shack-Hartmann