Description

Application

The system is designed for the extensive study of the recordings of the brain electric potentials, bioelectric signals in outpatient and in-patient facilities and is suitable for daily monitoring. It meets the requirements of Eurostandards for epilepsy care approved by the International League Against Epilepsy and provides the following:
• Surface EEG study;

• EEG Video Monitoring;

• EEG Daily Autonomous Monitoring;

• Conducting of Polysomnographic Examination;

• Using of Provocative Procedures;

• Recording and Analysis of Potentials.

Advantages
The system is ergonomic, compact, adapted for mobile application, equipped with a built-in multifunctional LCD display, it has capabilities for data transfer via Bluetooth and USB interfaces. The tp of the range bioelectrical amplifier provides high quality recording of EEG signals. The system can operate with or without mains power or being connected to a PC as it has both built-in batteries and data storage within its built-in memory unit. The combination of the unique functions and parameters of this system allow it to be used for all tasks relating to the recording and study of the brain electric potentials.

Technical Capabilities

This advanced software, which works on Windows and Linux OS, is supplied with the system. The basic software package makes it possible to perform the following: adaptive filtering of signals, editing and re-editing of recording, amplitude, spectral, bi-spectral, coherent and wavelet analysis, showing results in the form of charts, trend lines, tables, histograms and mapping, forming computer-assisted conclusion on the study results, storing study results in the patient database, exporting to standard file formats of analysis and EEG review.


Main technical characteristics

Number of EEG channels 22-32

EEG recording scheme monopolar, vertex, bipolar

Stimulation photo, audio, pattern

Sampling frequency Up to 8,000 Hz

EEG channel noises max. 0.3 mkV RMS

Number of bipolar channels 2-8

Connection of additional sensors ECG,EMG, EOG, breathing, snoring, tremor

PC connection USB, Bluetooth

Power supply USB, built-in batteries

Autonomous recording mode Up to 48h

The “Neuropolygraph” system is designed for the recording and analysis of the brain’s electric activity in outpatient and in-patient facilities. The unique parameters and functional capabilities of the “Neuropolygraph” system allows it to be used in all fields of medicine and science associated with EEG and the brain potential.


EEG "Neuropolygraph" system

Electroencephalograph "Neuropolygraph"
The biosignal amplifier has been developed using the latest microtechnologies. It has excellent quality EEG signal recording, a modern ergonomic design, it is compact, lightweight, is equipped with a built-in multifunctional LCD display displaying the operating mode impedance control. The “Neuropolygraph” amplifier power supply is either via a port or from built-in detachable batteries. The “Neuropolygraph” system has several operating modes. For routine examinations conducting and recording of induced potentials, the steady state mode is used, which provides the maximum functionality. For the record of longtime EEG, video monitoring, polysomnography the system has a mains free running mode. For this the amplifier’s energy supply comes from the battery pack, and the biosignal record is made on a memory card and transferred via the telemetric channel to the server (if needed). This is very convenient for both a patient and a doctor; during work in the mains free running mode it is possible not to use PC and this provides the added freedom of movement. The state of the art software which works on Windows, Linux, Apple OS X, and Android operation systems is supplied with the system. The number of channels is from 8 to 32 and is adjusted by the user. The “Neuropolygraph” amplifier can be integrated with external devices for photo, pattern and audiostimulation. There is the possibility of video monitoring with night illumination and of polysomnography with the connection of sensors of respiration, tremor, snore, temperature, body position, one or more ECG, EMG, EOG channels


Primary fields of the “Neuropolygraph” system application

Routine EEG examinations are carried out in the relaxed awareness state – a patient is seated in a comfortable chair with eyes closed. Duration of the examination is 20-30 minutes. An elastic cap with bridge or cup electrodes is used as an electrode system. The electrodes are placed on the head in accordance with the international pattern 10-20. To increase the detectability of epileptiform activity using the “Neuropolygraph” system, different functional tests are carried out – with opening and closing of eyes, with photostimulation of different frequency, with hyperventilation (deep breathing for 3-5 minutes), audiostimulation. If needed, tests with motor and mental exercise are carried out.


Longtime EEG monitoring, video monitoring, methods of longtime recording (8-10 hours) of patient encephalogram simultaneously with video and audio recording. Duration is the main advantage of the method since during routine EEG examinations (20-30 minutes) often it is impossible to differentiate epi-activity. Also the procedure is very important for the diagnosis of epilepsy in children. The manifestation of epileptic seizures in early age is particularly variable and obstructs their identification. The “Neuropolygraph” system has all the necessary technical software and ergonomic means for carrying out high quality longtime EEG recordings.

Polysomnography - the complex process of monitoring and recording of physiological parameters during sleep. The technique is the gold standard of examination in somnology and allows for the making of accurate diagnosis in most cases of somnopathy. Polysomnography is used in the diagnostics and study of such diseases as insomnia, bruxism, narcolepsy and in sleep periodic limb movement disorder. The number of apneic episodes and heart beats are the key indicators in patients affected with snoring.

Induced potentials present EEG recorded bioelectric reactions by different divisions of the central nervous system – cerebral cortex, brain stem or even spinal cord to a certain physical stimulus (flashing light, sound, rotating chess pattern or weak current discharge). From the results of such diagnostic stimulation, it is possible to assess the condition of optic, acoustic or somatosensory pathways. The method of induced potentials makes it possible to define, more accurately, the functional and organic nature of sensory disorders, for example, during differential diagnostics of hysteric amaurosis and true blindness. Using this method, it is possible to control the process of brain surgery, when a patient is unconscious, which helps to avoid nerve damage during surgical interference. Induced potentials are widely used for diagnostics of disseminated sclerosis and other severe organic diseases of the nervous system.


The capabilities of the “Neuropolygraph” system

The main operating modes of the system are the following:

• Mode of recording and writing EEG and biosignals on PC;
• Mode of free-running recording of EEG and biosignals;
• Mode of telemetric data transfer via a radio channel;
• Mode of impedance control;
• Mode of review and analysis of recorded data;
• Mode of patient data base;
• Export and import of data to external software packages.
In EEG recording mode the Neuropolygraph system makes it possible to:

The capabilities of “Neuropolygraph” system in the mode of EEG review and analysis
• conduct EEG and biosignal recording with autosave function in case of unexpected failure of the operation system;
• perform EEG recording without PC with data writing to the biosignal amplifier (Holter type);
• control the impedance of electrodes, including the grounding electrode;
• control telemetrically the biosignal amplifier operation;
• change montage and digital filtering parameters during writing;
• mark the events of interest on EEG record with markers;
• perform photo-audio stimulation as per specified pattern with the possibility of creating own stimulation patterns;
• provide load/store of the technique parameters;
• provide load/store of EEG wiring schemes;
• perform EEG monitoring without writing to PC;
• perform online spectral analysis with mapping;
• perform online coherent analysis with mapping;
• perform online detection of sharp waves;
• perform online removal of artefacts(ECG,EMG);
• perform synchronous recording of audio-video data.

• Visual review of the initial record with arbitrary parameters of scale and sweep;

• change of the editing and parameters of digital filtering, quick filtering of longtime records;
• unrestricted duration of analysis epochs;
• creation of several sets of analysis epochs for one record;
• report creation according to certain templates;
• quick printout of current page and printout of the whole record with the ability to preview before printing.;
• measurement of time and amplitude EEG parameters using bar cursor;
• magnifier for zoom view of selected EEG region;
• arbitrary adjustment of frequency ranges used for mathematical processing;
• arbitrary adjustment of event markers;
• load/store of calculation schemes of coherence and correlation;
• load/store of calculation schemes of trends;
• adjustable mode for record auto save on exit from program;
• video record review;
• removal of artefacts (ECG,EMG).


Mathematical processing capabilities of “Neuropolygraph” system

EEG amplitude mapping is one of the modern methods of mathematical processing of encephalographic curves with subsequent development of maps of instantaneous distribution of potential difference over the surface of the brain.

Amplitude mapping allows for the determining of the topical assignment of the components of averaged induced potentials or potentials associated with events reflecting the participation of different cortex divisions in information processing and also studying the neuronal mechanisms of cognitive and motor functions. The method is particularly effective for the evaluation of dynamic processes of bioelectric brain activity, mainly connected with epi-activity. The analysis of the amplitude maps reflecting the potential distribution in specific time intervals, makes it possible to obtain clear presentation of the origin of the phenomenon of interest, its distribution over the surface of the brain and dynamic changes of the process. During mapping local regions are detected in which epileptic discharges occur, which are hard to detect by traditional EEG reading. Such analysis gives additional useful information and makes it possible to predict more accurately the treatment results and the course and outcome of epilepsy. For example, amplitude mapping has been very accurate in the diagnosis of so called “benign epilepsy” with the focus in the area of the Rolandic fissure, thus isolating this variant from others which often have less optimistic prognosis. Rolandic epilepsy mainly occurs in children of 2-14 years and on reaching the age of 16 spontaneously subsides in 98.8% of patients. Currently 3D amplitude mapping is considered to be the most effective way to diagnose this.



EEG Spectral analysis -is intended for in-depth study of the frequencies of EEG recorded bioelectrical impulses above the brain surface.

So called power and amplitude of frequency characteristics of EEF biorhythms over a particular period of time are used as the main criteria of spectrogram analysis.

Such an approach makes it possible to evaluate the ratio of different rhythms within the EEG and most significantly to detect the frequencies which are not determined during visual analysis because of their small amplitude or on account of shielding by other rhythms. EEG spectrum power analysis is based on the fast Fourier transform method. At this time, some important common factors of EEG spectrum power distribution are known. For example, the EEG power spectrums of cortex anterior regions of healthy men have more complex nature than posterior ones which apparently is associated with mental activity and implementation of other cognitive psychical functions.

In the frontal-central parts of the brain the powers and frequencies of delta, beta, theta rhythms dominate and in the posterior parts of both hemispheres- the power of alpha frequencies prevails specific for the state of relaxation, enervation and drowsiness.

In brain pathology, the power of the EEG spectrum undergoes significant changes in comparison with the norm, according to the localization of the pathological process and the degree of brain damage.

Spectrum calculation is made for the selected montage for one or several epochs of the analysis of arbitrary duration. Each frequency range can be marked with its own color. Spectral analysis settings allows changes to be made in the number of Fourier transform points, weight window type and spectrum smoothing coefficient. Spectrum analysis data is joined into several types of tables i which show the levels of amplitude, power and instantaneous values of the spectrum in the selected frequency ranges.

It was found that in early infantile autism there is a higher delta rhythm power with simultaneous decrease of alpha-activity and also abnormal distribution of alpha and beta rhythms and levelling of hemispheric asymmetry. During logoneurosis the power of alpha activity in the posterior parts of the left hemisphere and anterior parts of the right hemisphere significantly increases. In healthy men, while listening and repeating phrases, the desynchronization of alpha-rhythm in the posterior regions of the left hemisphere and in patients with logoneurosis – of the right hemisphere. In healthy men, when activating imaginative thinking, alpha rhythm power increase was found only in the left hemisphere and in stuttering patients it was found both in the left and right hemispheres. Using EEG spectral analysis in depressive patients, the lengthening of REM sleep cycles can be found with simultaneous shortening of the latent time of their emerging and also the decrease of delta and increase of theta activity, and also the smoothening of the palpable differences in spectrum power between sleep and wakefulness phases. During latent depression, the asymmetry of EEG spectrum power indicators during REM sleep stage is registered and also more powerful spectrum of all frequencies of the biorhythms in the right hemisphere in comparison with the norm. During Alzheimer’s disease, the power increase of delta and theta rhythms and the decrease of alpha and beta activity are found.

Spectral Mapping. Any neurophysiological study is primarily a topical diagnostic tool, the main task of which is the search of the source of neuron abnormal or paroxysmal bioelectrical activity on the surface of the brain. For this purpose, on the basis of spectral analysis a method of spectral topographic mapping was developed, combining two complementary approaches: quantitative analysis of encephalographic curves in amplitude-power indicators and visual analysis, wherein topographic maps reflect the activity of the brain neurons in accordance with a specified color scale in the form of 2D or 3D image.

The building of the topographic maps of distribution of amplitude-power characteristics along the convexital cortex surface is possible on account of having a number of EEG recording channels; the possibility of dynamic analysis in several epoch is provided.



Coherent analysis. The term “coherent analysis” derives from Latin words “cohaerens” – connected and “cohaerere” – to be connected. In modern science coherence means the consistency of running processes in time. The coherence of brain electric signals is the quantitative indicator of the synchronism of involving of different cortical zones during their functional interaction providing the integrative activity of brain structures. Since brain electrical activity is closely associated with its functional activity, coherence indicates the involvement of different cortical zones in providing brain function performance, it other words it is the quantitative representation of the integrative activity level of brain structures. Coherence reflects the degree of consistency of the functional interactions between different cortical regions. The integration level of the cortex regions should be adequate for optimal performing of functions.

The values of coherence vary from 0 to 1. In this case the higher coherence value the more consistent the activity of a region with another. One of the main advantages of the coherent analysis is the independence of coherence coefficients from the signal amplitude of different brain regions. However, the use of the coherent method of EEG processing is limited still mainly to scientific purposes on account of the complexity of the process of bioelectrical signal processing which requires the use of complex mathematical equipment. But today, thanks to rapidly developing digital technologies the problem is being solved.

Coherence calculation is made by one or several periods. In order to perform coherence calculations a random set of pairs of montage leads are selected. The calculation results are presented in the form of coherence value tables in selected frequency ranges.

Coherence mapping. A mapping method was developed on the basis of coherence analysis. This modern method of mathematical processing of electroencephalographic curves reflects the distribution of coherence coefficient values within the specified variability limits. During coherent mapping the number of encephalographic record channels is of great importance. The more the number of leads of an encephalograph the more information-intensive is the result of the coherent analysis. According to the world literature data, the coherent analysis proved itself in the psychology of developmental age and psychiatry.

Today EEG coherent analysis is successfully used for objective assessment of the synchronism of the functional activity of brain regions for the purpose of development of differentiated diagnostic and treatment and rehabilitation programs which creates the realistic approaches to the high quality delivery of high-tech medical care.



Trend analysis. For extended period recording trend analysis is used – the chart of a parameter change during the whole recording.

The “Neuropolygraph” program system allows calculations of the trends of amplitude, power, spectrum or coherence in the specified frequency range for the selected leads of an amplitude-integrated EEG, average and maximum frequency, amplitude and rhythm indices, amplitude and time parameters of polygraph channels, the number of sharp waves.

The set of trend parameters – trend schemes- can be formed randomly and be kept till next use. Navigation in the trend window makes it possible to quickly go to the record area corresponding to the cursor.



Correlation analysis. In the “Neuropolygraph” program system the correlation calculation is made in the specified time interval for pairs of leads (mutual correlation) or for one lead (autocorrelation). The correlation function is normalized by amplitude and centered relative to the average value. It has a range of values from -1 to +1.

The correlation EEG analysis makes it possible to qualitatively assess the presence of interdependency, their strength and directivity between bioelectrical processes taking place in different brain regions, reveal common regularities in the occurrence of some or other variants of cortex neuronal activity. The current methods of statistical processing of quantitative EEG analysis makes it possible only to categorize the bioelectrical activity phenomena, assign them to periodic or aperiodic events and reveal the periodicity of their appearance. By contrast, correlation EEG analysis provides a method of dominant components of bioelectrical activity of brain neurons. The correlation analysis, that uses mutual correlation functions allows for weak bioelectric impulses to be shown. The cross-correlation EEG analysis, also called the mutual correlation method, makes it possible to determine the functional interactions between different cortex locuses.



Period analysis.

The period analysis is based on the measurements of periods between the characteristic points of encephalographic curves – wave tops, weak peaks or zero crossing.

The period EEG analysis makes it possible to calculate the average values of wave amplitude, their confidence intervals, average wave periods and their dispersion, compute EEG rhythm indices with high accuracy based on the sum of all wave periods of the selected frequency range.

The prototype of the present type of mathematical EEG processing is the Fourier analysis. However, the period EEG analysis has a bigger interference resistance and its results depend to a far lesser degree on the effect of single high-amplitude events, for example, on interferences caused by the patient moving during the EEG. The period analysis is performed by one or several periods for all leads of the present electrode mounting scheme in the selected frequency range. Before starting the period analysis, it is necessary to specify frequency ranges and the averaging mode by selected periods. It is also necessary to specify the parameter type histogram-frequency or rhythm amplitude. Depending on this, the average and maximum rhythm frequency or the average and maximum amplitude and the rhythm index of an analyzed periods are displayed on the histograms.



Mapping of parameters of periodic analysis. The results of the period analysis can be represented in the form of maps of amplitude-time parameter distribution along the convexital surface of the cortex.

This method of mathematical EEG processing shows the variability of values of the calculated amplitudes and periods of the bioelectrical impulse waves within the specified limits.

During period mapping the wiring configuration of electrode placing and the number of encephalographic recording channels are also of great importance. The greater the number of channels an encephalograph has, the more informative the results of the period analysis. However, it should be taken into account that at this time no common standards for performing the period analysis and mapping have been finalized.



Bi-spectral and bi-coherent EEG analysis. The bi-spectral analysis describes the observations made at two EEG signal frequencies. The procedure of bi-spectral analysis includes the use of the phase information obtained from the fast Fourier transformation and the calculations of inter-frequency phase relations. It is used to look for evidence of non-linear signal interactions.

All complex EEG signals can be divided into constituent sinusoids using the fast Fourier transformation. From each analyzed period three indicators are obtained – frequency, power and phase.

The main parameter of the method is so called bi-spectral analysis, which adequately reflects the depth of general anesthesia. Anesthesiologists call this indicator “brain window”. To provide maximum speed of bi=spectral analysis in conditions of emergency medicine anesthesiologists use special electrodes which are applied using an adhesive glue. They provide high quality EEG recording, the mounting of the electrodes under 10 seconds. Today the bi-spectral analysis is fully adapted to take account of the effects of r anesthesia and became the standard practice in anesthetic care.

The bi-coherent EEG analysis is used for the study of interhemispheric phase relationships between low and high frequency rhythms in the range of 0.5- 30 Hz. It was found that these relationships are quite strictly determined by gender characteristics, the type of executed activity, temperature characteristics of a subject, intelligence quotient and lateral brain organization.



Wavelet analysis provides a method of mathematical processing of encephalograms giving the ability to study the frequency components of bioelectrical impulses which function graph presents dampened waveform oscillations with amplitudetending to zero.In the course of the integral transformation of EEG curves so called wavelet coefficients. On the basis of the wavelet analysis the matrix of wavelet coefficients is built reflecting the proportion of one or another frequency in the spectrum of recorded biorhythms at a certain point.

The wavelet analysis allows evaluation of the activity of transient bioelectrical processes in the brain. When used together with photostimulation it is possible to get fundamentally new data on the dynamics of amplitude-frequency indicators of an encephalogram. This makes it possible to determine the regularities of the unsteady EEG change during functional tests with photostimulation, hyperventilation, psychoemotional load etc.

The advantages of the wavelet analysis lay in a possibility of decomposition of bioelectrical signal structure into frequency and time components; b)analysis of short periods containing a small number of periodic oscillations; variability of selection of the basic parameters whereby bioelectric impulses are analyzed; effective analysis of noisy signals with the enhancement of a useful component and noise.

Wavelet analysis has a large number of uses including but not limited to the the study of epi-activity, sleep and wakefulness phases.



Independent component analysis(ICA) relates to multivariate statistics and presents the extension of the principal component method and factor analysis.

Using the analysis any signals are decomposed into the form of the superposition of independent sources (components). In neurophysiology over several decades efforts have been made to improve the quality of EEG recording. It is important to remove noise from power supply and system noise, of myocardium electrical activity, all kinds of muscle contractions etc.

Recently independent component analysis has been used in modern encephalographs as a way of detuninginterfering noises and enhancing useful signal.

Using the program system “Neuropolygraph” the independent component analysis is performed by an active period for all channels of the wiring scheme of EEG electrodes. The analysis can be used, for example, to remove the results due to cardio, myo- signals or other origin.



Program module for pathological source activity localization is used to detect the sources of abnormal electric activity of the brain, represented for any specific time in the form of one or several equivalent electric dipoles. Single point amplitude values of multichannel EEG are used as input information regardless of the wiring configuration. For each analyzed time point the calculations of three dimensional coordinates and vector moments with a set number of sources, achieve 95% confidence intervals as well as the dipole coefficient characterizing the adequacy of the used model. The results are produced in orthogonal projections on standard section on the brain atlas or on the tomographic image of a patient’s head. The possibility exists for building amplitude maps of EEG potential distribution, potential maps for the dipole model as well as ECOG potential maps on the surface of the brain cortex.

The program BrainLoc may be useful both in clinical practice, since it enables accurate visualization of abnormal focuses deep in the brain in the presence of tumors or epileptic activity (functional EEG tomography), and in scientific research, since it makes it possible to trace the dynamic motion of the electrical activity centers in the brain structures by different impacts, for example, mental load while recoding the induced potentials of different modality, during the study of the wave complex development dynamics, when investigating the sources of rhythmic activity generation in different frequency ranges etc.