Module for health assessment of the newborn “Apgar-timer”
The module is used in delivery rooms, as well as in simulation and training centers for medical personnel training in cardiopulmonary resuscitation of newborns.
Part number:
Supplier:
Shvabe Description
The module is designed to assess the health condition of the newborn on the Apgar scale. The main mode of operation of the device is the formation of sound signals at certain intervals after the birth of the baby to indicate to medical personnel the need for a regular assessment of the the newborn condition, as well as for cardiopulmonary resuscitation, including artificial lung ventilation (hereinafter - ALV) and external cardiac massage (hereinafter - ECM), which allows you to synchronize the work of medical personnel during resuscitation.
Dimensions 155/105/70mm
Weight 0.3 kg
Power 700VA
Service life 3 years
Number of batteries of galvanic type LR6/AA 2 pcs
Voltage 2.0-3.3V
Power Consumption 330mA
Operating modes:
Waiting mode: minimum power consumption, all settings are stored in memory
Account mode: sounding for 1,2,5,10,20,30,40,50 minutes
Metronome ALV mode (artificial ventilation of the lungs): sound signals from 20 to 80 times/min
Metronome ECM mode (external cardiac massage): sound signals with a frequency of 4 times the frequency of the signal ALV
Displaying the time of birth: the last time the Account mode was turned on
Display of the end time of resuscitation: the time of the time the Account mode was turned-off
Display current real time: real time, with seconds sync function
Indicator "discharge of batteries": low charge indication, for timely replacement of the power source, storage of all information for 5 minutes after power-off
Waiting mode: minimum power consumption, all settings are stored in memory 5 6 7 8 9 10
Dimensions 155/105/70mm
Weight 0.3 kg
Power 700VA
Service life 3 years
Number of batteries of galvanic type LR6/AA 2 pcs
Voltage 2.0-3.3V
Power Consumption 330mA
Operating modes:
Waiting mode: minimum power consumption, all settings are stored in memory
Account mode: sounding for 1,2,5,10,20,30,40,50 minutes
Metronome ALV mode (artificial ventilation of the lungs): sound signals from 20 to 80 times/min
Metronome ECM mode (external cardiac massage): sound signals with a frequency of 4 times the frequency of the signal ALV
Displaying the time of birth: the last time the Account mode was turned on
Display of the end time of resuscitation: the time of the time the Account mode was turned-off
Display current real time: real time, with seconds sync function
Indicator "discharge of batteries": low charge indication, for timely replacement of the power source, storage of all information for 5 minutes after power-off
Waiting mode: minimum power consumption, all settings are stored in memory 5 6 7 8 9 10