The magneto-resistant photomultiplier tube FEU-188
The PMT-188 photomultiplier tube has a bilelite photocathode and a single-stage multiplication system with a dynode made in the form of a grid electrode with a grid frequency of 100 lines / mm.
Part number:
Supplier:
The Ruselectronics holding companyDescription
DESCRIPTION
FEU-188 is manufactured in a glass cylinder with an end-in optical input, with flexible leads. The input window is made of UV-borosilicate glass
Application
photodetectors operating under exposure to magnetic fields up to 4 T and radiation emissions up to 2 kGy
Main settings
Photocathode Material SbKCsO
The diameter of the photocathode, mm 22
The diameter of the device, mm 26.5
Length, mm 46
Power supply, V 1000
Spectral sensitivity range, nm 220 ÷ 650
Light sensitivity of the photocathode, µA / lm ≥60
Quantum efficiency of the photocathode at Ȝ = 420 nm,% ≥18
Dark current, NA ≤2
Gain under normal conditions, times ≥8
Gain in a magnetic field with intensity H = 4 TL, times ≥6
FEU-188 is manufactured in a glass cylinder with an end-in optical input, with flexible leads. The input window is made of UV-borosilicate glass
Application
photodetectors operating under exposure to magnetic fields up to 4 T and radiation emissions up to 2 kGy
Main settings
Photocathode Material SbKCsO
The diameter of the photocathode, mm 22
The diameter of the device, mm 26.5
Length, mm 46
Power supply, V 1000
Spectral sensitivity range, nm 220 ÷ 650
Light sensitivity of the photocathode, µA / lm ≥60
Quantum efficiency of the photocathode at Ȝ = 420 nm,% ≥18
Dark current, NA ≤2
Gain under normal conditions, times ≥8
Gain in a magnetic field with intensity H = 4 TL, times ≥6