Description

DNV-140I can be used to control and line up the high voltage power circuits of the power stations, wireless devices, electrophysical and X-ray equipment etc.

Direct current input voltage, kV 140
Alternating (50 Hz) current input voltage, kV 100
Pulse voltage, kV 250
Division factor 1/5,000 Input resistance,
MO, min 304 Input capacity, pF, max 144
Operating frequency 8 Step response time, ns, max 43
Voltage divider overall dimensions, mm, max 360x1,100
Weight, kg, max 26
Cable length (RG214/U), m 10