Description

Standard configuration:

Inert gas supply system,
Seal leak test system,
Vacuum cleaning system,
In-box temperature transducer,
Oxygen transmitter,
Moisture transmitter,
Aerosol pre-filter at the glovebox air outlet that is DN50 pipe branch with a ball valve assembled with electric actuator and manual override device,
Repair ventilation (DN150 pipe branch with a ball valve assembled with electric actuator),
LED light,
In-box differential pressure sensor,
Junction boxes to connect electric and lighting equipment,
Inlet and outlet DN15 pipes for decontaminating solutions,
Maintenance door.
The glovebox configuration options can be adjusted on the Customer’s request (quantity and layout of fittings, biological shielding etc.).

Key specifications:

Material Steel 12Х18Н10Т to GOST 5632-2014 or AISI 321 (AISI 304)
Dimensions 1200 mm(W) х 2500 mm (H) х 1700 mm (D)
Leak tightness ≥ 6.7*10-4 m3Pa/s
Oxygen level ≤ 50 ppm
Moisture level ≤ 50 ppm
Negative pressure 200 Pa
Air purification from radioactive and nonradioactive aerosols
performed by pre-filter ≥ 99.995 %
Material and thickness of biological shielding
at operating area Shielding plate: 20 mm steel + 20 mm low density polyethylene.
Window: 16 mm shielding glass + 10 mm polycarbonate