Description

Specifications
Switching voltage range, V 0,05-72
Switching current range, mА 0,1-250
Switching power, W, max 10
Life, min 105
Output electrical resistance:

• at closed contacts (at (100±10)mА), Ohm, max

• at open contacts, kOhms, min

0,5
200

If sensor and magnet are located parallel contacts should be:

• closed – at the distance between them, mm

• open – at the distance between them, mm
8 and less

45 and more

Allowable offset of sensor and magnet, mm, max 7
Insulation resistance between leads of sensor:

• in normal climatic conditions, Ohms, min

• at high relative humidity 98%, Ohms, min

5 · 106
2 · 105

Breakdown voltage between sensor leads and case, VAC /VDC , min 500 / 700
Operating temperature range, °С -40 … +45
High humidity at +25 0С, %, max 98
Vibration proof at 10 to 35 Hz, m·sec-2 (g), max 4,9 (0,5)
Failure time, h, min 200000
Life time, years, min 8
Sensor/magnet weight, g, max 2,33/1,13
Installation:
For installation a plastic surface should be drilled.