Pacemaker three-chamber VEGARITM
Annually, heart failure is diagnosed for the first time in 3 out of 1,000 people aged 33–65 years and in 10 out of 1,000 people over 65 years old. In 2018, the annual need for implantation of three-chamber pacemakers can be 48.65 thousand people. The development of a domestic three-chamber pacemaker will significantly reduce the cost of the product compared with foreign analogues and provide opportunities for providing high-tech medical care of this type to a greater number of patients.
Part number:
Description
Purpose
Three-chamber pacemakers are designed for individual cases of treatment of CCF functional class (FC) III and IV ("Electrophysiological methods for treating CCF" collection "National recommendations of VNOK and OSSN for the diagnosis and treatment of CCF").
Benefits
A pacemaker designed to provide:
single-chamber, two-chamber and three-chamber stimulation modes;
adaptation of the frequency of stimulation depending on physical activity;
continuous operation for 8 years with 100% stimulation in standard mode on 3 channels;
recording of diagnostically important episodes of an electrocardiogram in automatic mode;
the ability to interact with a programmer through a wireless connection.
Specifications
The three-chamber pacemaker uses three electrodes, one of which is placed in the atrium, and the other two in the right and left ventricle, performing cardio-resynchronization and providing physiological movement of blood through the chambers of the heart.
A three-chamber pacemaker is able to stimulate three sections of the heart at once: the atrium, the right and left ventricle, providing physiological movement of blood through the heart sections. It can also work in 1-, 2- and 3-chamber stimulation modes.
The materials used to make a pacemaker are biologically inert.
Composition
The three-chamber pacemaker system includes:
- an electric pulse generator comprising an electronic microcircuit and a power source that are installed inside a sealed enclosure;
- electrodes, which are a special spiral conductor with sufficient flexibility to withstand torsion and flexion caused by body movements and contractions of the heart.
The composition of the product:
three-chamber pacemaker;
endocardial bipolar electrode to stimulate the right atrium; Vega V
endocardial bipolar electrode to stimulate the right ventricle "Vega A";
endocardial bipolar electrode to stimulate the left ventricle "Vega L";
endocardial monopolar electrode to stimulate the left ventricle "Vega LU"
Three-chamber pacemakers are designed for individual cases of treatment of CCF functional class (FC) III and IV ("Electrophysiological methods for treating CCF" collection "National recommendations of VNOK and OSSN for the diagnosis and treatment of CCF").
Benefits
A pacemaker designed to provide:
single-chamber, two-chamber and three-chamber stimulation modes;
adaptation of the frequency of stimulation depending on physical activity;
continuous operation for 8 years with 100% stimulation in standard mode on 3 channels;
recording of diagnostically important episodes of an electrocardiogram in automatic mode;
the ability to interact with a programmer through a wireless connection.
Specifications
The three-chamber pacemaker uses three electrodes, one of which is placed in the atrium, and the other two in the right and left ventricle, performing cardio-resynchronization and providing physiological movement of blood through the chambers of the heart.
A three-chamber pacemaker is able to stimulate three sections of the heart at once: the atrium, the right and left ventricle, providing physiological movement of blood through the heart sections. It can also work in 1-, 2- and 3-chamber stimulation modes.
The materials used to make a pacemaker are biologically inert.
Composition
The three-chamber pacemaker system includes:
- an electric pulse generator comprising an electronic microcircuit and a power source that are installed inside a sealed enclosure;
- electrodes, which are a special spiral conductor with sufficient flexibility to withstand torsion and flexion caused by body movements and contractions of the heart.
The composition of the product:
three-chamber pacemaker;
endocardial bipolar electrode to stimulate the right atrium; Vega V
endocardial bipolar electrode to stimulate the right ventricle "Vega A";
endocardial bipolar electrode to stimulate the left ventricle "Vega L";
endocardial monopolar electrode to stimulate the left ventricle "Vega LU"