Device for storage of donor platelets " Platelet»
A device for storing donor platelets agitator (de-48 and de-96) is intended to ensure the fullpreservation of the functional properties of donor platelets in the conditions of their storage in plastic
containers while maintaining a constant temperature (22°C) with continuous stirring (shaking) in accordance with the "Technical regulations about safety requirements of blood, its products, blood-substituting solutions and technical means used in transfusion-infusion therapy", approved by RF Government resolution No. 29 of 26.01.2010, recommendations of the Council of Europe and who on the preparation, use and quality assurance of blood components.
Part number:
Description
Dignities
the principle of operation is based on peltier modules, which ensures quietness, safety and reliability;
quick access to operating temperature-30 min;
simple and convenient operation;
protection from power surges;
electrical safety;
ease of disinfection;
stability at work, thanks to the low center of gravity;
manufacturability of the device provides convenience in its maintenance.
Execution
Version 1 - 48 of containers
Version 2-96 containers
Overall dimensions (LxWxH)
Version 1-875x635x836 mm
Version 2-875x1165x836 mm
Agitator-735x355x472 mm
The power of the device
from AC network with voltage 220 V
in emergency mode
- at a deviation of supply voltage ± 10 % with a frequency of 50 Hz
- from the battery voltage of 12 V± 10 %, 3 A * h
Power consumption
Version 1-not more than-370 VA
Version 2-not more than-690 VA
Weight
Version 1 - 85 kg
Version 2-160 kg
Nominal temperature in the temperature control chamber: + 22°C with a temperature tolerance of ±
2°C.
Nominal frequency of reciprocating motion of the agitator platform: 65 min, with a permissible
deviation of the frequency of reciprocating motion of the platform ± 10 min-1.
The nominal amplitude of the horizontal movement of stirrer platform: 20 mm, with a tolerance to
control the magnitude of the horizontal platform displacement of ±5 mm.
The period of registration of the process parameters storage of platelet concentrate: in the internal
built-in flash memory every 15 minutes.
The period of registration of platelet concentrate storage parameters: in the internal built-in flash
memory with the power supply disconnected for 7 days.
The device has a light and sound alarm of emergency situations (the temperature in the chamber
beyond the permissible limits, the opening of the chamber door, the lack of power supply voltage, the
lack of reciprocating motion of the agitator platform).
The device is equipped with a usb connector for communication with a personal computer.
The device is used in medical hospitals, at stations and in blood transfusion departments, in surgical and intensive care units of hospitals and clinics, as well as in research medical institutions for resuscitation,
treatment of oncological and hematological diseases, cardiac and other operations accompanied by acute blood loss
the principle of operation is based on peltier modules, which ensures quietness, safety and reliability;
quick access to operating temperature-30 min;
simple and convenient operation;
protection from power surges;
electrical safety;
ease of disinfection;
stability at work, thanks to the low center of gravity;
manufacturability of the device provides convenience in its maintenance.
Execution
Version 1 - 48 of containers
Version 2-96 containers
Overall dimensions (LxWxH)
Version 1-875x635x836 mm
Version 2-875x1165x836 mm
Agitator-735x355x472 mm
The power of the device
from AC network with voltage 220 V
in emergency mode
- at a deviation of supply voltage ± 10 % with a frequency of 50 Hz
- from the battery voltage of 12 V± 10 %, 3 A * h
Power consumption
Version 1-not more than-370 VA
Version 2-not more than-690 VA
Weight
Version 1 - 85 kg
Version 2-160 kg
Nominal temperature in the temperature control chamber: + 22°C with a temperature tolerance of ±
2°C.
Nominal frequency of reciprocating motion of the agitator platform: 65 min, with a permissible
deviation of the frequency of reciprocating motion of the platform ± 10 min-1.
The nominal amplitude of the horizontal movement of stirrer platform: 20 mm, with a tolerance to
control the magnitude of the horizontal platform displacement of ±5 mm.
The period of registration of the process parameters storage of platelet concentrate: in the internal
built-in flash memory every 15 minutes.
The period of registration of platelet concentrate storage parameters: in the internal built-in flash
memory with the power supply disconnected for 7 days.
The device has a light and sound alarm of emergency situations (the temperature in the chamber
beyond the permissible limits, the opening of the chamber door, the lack of power supply voltage, the
lack of reciprocating motion of the agitator platform).
The device is equipped with a usb connector for communication with a personal computer.
The device is used in medical hospitals, at stations and in blood transfusion departments, in surgical and intensive care units of hospitals and clinics, as well as in research medical institutions for resuscitation,
treatment of oncological and hematological diseases, cardiac and other operations accompanied by acute blood loss