Complex for automated assessment of the functional state of the cardiovascular system "Cardiometer-MT"
12-channel wireless electrocardiograph with automatic interpretation and support of Internet ECG telemetry at rest, working in conjunction with an Internet server (Cardioserver), the software of which is provided as part of the complex. The complex KFS-01.001 "Cardiometer-MT" fully complies with the standard of equipping emergency medical stations and emergency departments of clinics and hospitals in accordance with Appendix No. 5 of the Order of the Ministry of Health of the Russian Federation of June 20, 2013 No. 388n. including emergency medical care. "
Part number:
Supplier:
Shvabe Description
Benefits:
- Remote automatic ECG decoding.
- Responsible for building telemedicine system.
- Can be installed in mobile mobile centers.
- Tested in the regions of Russia, on the objects of air and railway transport.
- Available to use by junior medical staff.
- Ability to work online and offline.
- Optimization of costs for ECG studies.
- Reducing the load on the specialist.
Input range 0.03-10 mV
Sampling frequency of the input continuous signal 32 kHz
Minimum common mode attenuation 100,000
Maximum level of internal noise brought to the input of 20 µV
The maximum coefficient of interference between channels 1.6%
The minimum total input impedance at a frequency of 10 Hz 100 MΩ
The number of bits of the analog-to-digital converter 24
Communication with a computer or mobile phone wirelessly
BLUETOOTH
Dimensions of ASI, mm 135 x 72 x 24
Maximum weight of ASE with batteries and discharge harnesses, kg 0.3
- Remote automatic ECG decoding.
- Responsible for building telemedicine system.
- Can be installed in mobile mobile centers.
- Tested in the regions of Russia, on the objects of air and railway transport.
- Available to use by junior medical staff.
- Ability to work online and offline.
- Optimization of costs for ECG studies.
- Reducing the load on the specialist.
Input range 0.03-10 mV
Sampling frequency of the input continuous signal 32 kHz
Minimum common mode attenuation 100,000
Maximum level of internal noise brought to the input of 20 µV
The maximum coefficient of interference between channels 1.6%
The minimum total input impedance at a frequency of 10 Hz 100 MΩ
The number of bits of the analog-to-digital converter 24
Communication with a computer or mobile phone wirelessly
BLUETOOTH
Dimensions of ASI, mm 135 x 72 x 24
Maximum weight of ASE with batteries and discharge harnesses, kg 0.3
Specification
1. KFS-01.001_Cardiometer-MT_rus.pdf