MX-400 water treatment system
The MX-400 water treatment system is designed to purify water from wells from suspended matter, colloids, bacteria, viruses, various compounds (iron, manganese, copper, sulfur, phosphorus), organic substances, dissolved salts (including compounds of one-, two- and polyvalent metals ), as well as its subsequent storage and delivery under pressure to the consumer’s network. It can be used to supply water to individual houses with simultaneous accommodation of up to 40 people at a consumption rate of 250 l / person. per day.
Part number:
Supplier:
Shvabe Description
- The system consists of 3 nodes mounted in a single package: a water treatment unit, a storage unit for purified water, a unit for dispensing purified water to a consumer’s network.
- Pumping station when using MX-400 is not required.
System dimensions, mm, not more
1000x600x1800
Average productivity of purified water (at a temperature of initial water + 40 ° С), l / h, not less
400
Peak consumption of purified water, m3 / h, not less
2.0
Purified water pressure at the outlet of the system, MPa, not less
0.2
Dry weight of the system, kg, not more
210
Power supply, V
220
Power consumption of the system, kW, not more
1.85
Drainage water consumption, m3 / h, not more
0.4
Drainage water pressure at the outlet of the system, MPa
0 ... 0.5
Initial water inlet pressure, MPa, not more
0.4
Allowable loads on the system case, g
up to 10 (with a frequency of up to 1 Hz)
Ambient temperature during storage and operation, hail. WITH
from - + 5 to +40
Resource before overhaul, m3 of purified water, not less
2000
Assigned resource, m3 of purified water, not less
12,000
Manufacturer JSC "Research Institute" Polyus "
Water treatment characteristics
Indicators, units measurements
Source water Purified water
SanPiN 2.1.4.1074-01. Drinking water
Chromaticity, hail.
50
0
five
Smell points
five
0
one
Taste, points
five
0
one
Kaolin turbidity, mg / l
200
0 0.5
Total iron, mg / l
11.5
0.1 0.3
Manganese, mg / l
0.5
0.05
0.05
Sulphides, mg / l
0.1
0
0,003
Oxidation, mg O2 / l
10 0.5
2
Ammonium, mg / l
one
0.03
0.05
Total hardness, mEq / l
20
1.5
7
Total mineralization, mg / l
6000
300
1000
Nitrates, mg / l
200
0.8
five
Chlorides, mg / l
1500
100
150
Sulfates, mg / l
2800
100
150
Phosphates, mg / l
ten
0.5
3.5
Strontium, mg / l
40
four
7
Microbiological indicators: a) bacteria (forming and not forming spores), bw / l
1 ∙ 106
0
-
Microbiological indicators: b) viruses, PFU / l
1 ∙ 106
0
-
- Pumping station when using MX-400 is not required.
System dimensions, mm, not more
1000x600x1800
Average productivity of purified water (at a temperature of initial water + 40 ° С), l / h, not less
400
Peak consumption of purified water, m3 / h, not less
2.0
Purified water pressure at the outlet of the system, MPa, not less
0.2
Dry weight of the system, kg, not more
210
Power supply, V
220
Power consumption of the system, kW, not more
1.85
Drainage water consumption, m3 / h, not more
0.4
Drainage water pressure at the outlet of the system, MPa
0 ... 0.5
Initial water inlet pressure, MPa, not more
0.4
Allowable loads on the system case, g
up to 10 (with a frequency of up to 1 Hz)
Ambient temperature during storage and operation, hail. WITH
from - + 5 to +40
Resource before overhaul, m3 of purified water, not less
2000
Assigned resource, m3 of purified water, not less
12,000
Manufacturer JSC "Research Institute" Polyus "
Water treatment characteristics
Indicators, units measurements
Source water Purified water
SanPiN 2.1.4.1074-01. Drinking water
Chromaticity, hail.
50
0
five
Smell points
five
0
one
Taste, points
five
0
one
Kaolin turbidity, mg / l
200
0 0.5
Total iron, mg / l
11.5
0.1 0.3
Manganese, mg / l
0.5
0.05
0.05
Sulphides, mg / l
0.1
0
0,003
Oxidation, mg O2 / l
10 0.5
2
Ammonium, mg / l
one
0.03
0.05
Total hardness, mEq / l
20
1.5
7
Total mineralization, mg / l
6000
300
1000
Nitrates, mg / l
200
0.8
five
Chlorides, mg / l
1500
100
150
Sulfates, mg / l
2800
100
150
Phosphates, mg / l
ten
0.5
3.5
Strontium, mg / l
40
four
7
Microbiological indicators: a) bacteria (forming and not forming spores), bw / l
1 ∙ 106
0
-
Microbiological indicators: b) viruses, PFU / l
1 ∙ 106
0
-